Advanced Integrated Electrical Winding Instrument
Project Image
The application performs winding test such as AC and DC Hipot, Resistance, Surge and Rotation Direction tests.
PSA developed the GUI and IPC components to decouple the GUI from the control system. The IPC component handled the message communication between the control system and the GUI. The design of the IPC used a concept called Notifiers. Notifiers connect objects indirectly, replacing pointers and direct functions calls. Since they're anonymous, notifiers reveal nothing about the implementation, interface, or even the existence of the connected objects, leaving them independent of one another. By reducing IPC dependencies this approach reduced application complexity.